Animal & Cell Hypoxia Workstation
DY-WC-D

Left workstation for animal research
Right workstation for cell research

The Dual Hypoxia Workstation is a specialized research tool that features two separate and spacious workspaces. It is designed to maintain stable and controlled hypoxic conditions that are essential for animal and cell culture research.

The left workspace of the workstation offers precise oxygen control from 0.5% to 20.9% with 0.1% increments. Additionally, it features an optional carbon dioxide monitor and alarm.

The right workspace provides precise oxygen control from 0.1% to 20.9%, carbon dioxide control from 0.1% to 20% with 0.1% increments, and relative humidity control up to 75% with 0.1% increments.

The dual hypoxia workstation comes in various sizes and options, such as the HEPA system, CO2 monitor system, and temperature control. Furthermore, customized workstations can also be provided, enabling researchers to have greater flexibility in their research.

Left workstation (Animal):

  • Constantly control and monitor internal environment
  • Separate O2 Control: 0.5% – 20.9%, in 0.1% increments
  • One-touch calibration for O2 sensor

Right workstation (Cell):

  • Constantly control and monitor internal environment
  • OControl: 0.1% – 20.9%, in 0.1% increments (Optional Anaerobic System)
  • COControl: 0.03% – 20.0%, in 0.1% increments
  • One-touch calibration for Oand CO2 sensor
  • Temperature Control: 5°C above ambient up to 45°C, in 0.1°C increments
  • Humidity Control: Room humidity to 75%, in 0.1%increments
  • Advanced Airway Design:
    Ensures a high level of homogeneity in the workstation’s gas distribution
  • Special manufacturing technique:
    The top, front and bottom panels are moldedfrom a single piece of acrylic to reduce condensation and microbial growth
  • Direct-access operation system:
    The sleeves are made of a soft, skin-friendly material and an efficient vacuum pump direct access to the workstation only 8-12 seconds
  • Unique interlock purge technique:
    During the interlock purge the user can select the oxygen concentration required in the interlock

Left workstation (Animal):

  • CO2 Monitor and alarm: 0.5% – 20.0%, in 0.1% increments; with one-touch calibration
  • Temperature Control: 5°C above ambient up to 45°C, in 0.1°C increments
  • Programmable four-stage hypoxic cycle:
    Can stimulate the sample by change of O2 and CO2 concentration automatically
  • HEPA System: high level of cleanliness
  • Removable Front Panel: integrate equipment into workstation
  • Cable Port: integrate equipment into workstation
  • Vacuum Suction Pipe

Right workstation (Cell):

  • Programmable four-stage hypoxic cycle:
    Can stimulate the sample by change of Oand CO2 concentration automatically
  • Anaerobic System: hypoxia & anaerobic in one workstation
  • HEPA System: high level of cleanliness
  • Removable Front Panel: integrate equipment into workstation
  • Cable Port: integrate equipment into workstation
  • Single Plate Entry System
  • Vacuum Suction Pipe
  • High Oxygen Chamber

Each internal size (mm): 420(H)*800(W)*460(D); 154.6L

External size (mm): 600(H)*2000(W)*660(D)

Interlock size (mm): 245(H)*288(W)*257(D); 18.1L

Other Animal Hypoxia Instruments

Hypoxia Workstation

Only need cell hypoxia research?
Click here!

Animal Hypoxia Workstation

Only need animal hypoxia research?
Click here!